Article: Chronic hypobaric hypoxia induces tolerance to acute hypoxia and up-regulation in alpha-2 adrenoceptor in rat locus coeruleus.
Full Text (publisher's website) ; Article Metadata ; Article Data (extracted) Chang KC; Yang JJ; Liao JF; Wang CH; Chiu TH; Hsu FC Brain Res., 2006
Table 1 Resting membrane properties of the control and exposed LC neurons
Data were presented as mean ± SEM.⁎⁎⁎P < 0.001 compared to control.
Control (n = 84) | Exposed (n = 105) | |
Resting membrane potential (MP) (mV) | −55.8 ± 0.6 | −56.3 ± 0.8 |
Membrane input resistance (IR) (MΩ) | 134 ± 8 | 143 ± 9 |
Spontaneous firing rate (FR) (Hz) | 2.8 ± 0.2 | 1.8 ± 0.1⁎⁎⁎ |
Inferred neuron-electrophysiology data values
Neuron Type | Neuron Description | Ephys Prop | Extracted Value | Standardized Value | Content Source |
---|---|---|---|---|---|
Locus coeruleus noradrenergic neuron | Locus coeruleus alpha-2 adrenoceptor expressing noradrenergic neuron | spontaneous firing rate | 2.8 ± 0.2 | 2.8 (Hz) | Data Table |
Locus coeruleus noradrenergic neuron | Locus coeruleus alpha-2 adrenoceptor expressing noradrenergic neuron | resting membrane potential | -55.8 ± 0.6 | -55.8 (mV) | Data Table |
Locus coeruleus noradrenergic neuron | Locus coeruleus alpha-2 adrenoceptor expressing noradrenergic neuron | input resistance | 134.0 ± 8.0 | 134.0 (MΩ) | Data Table |